<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-06 22-40-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -12 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 71 kHz 10040 7,7092
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
5,9 dBr 7,39 dBr 8,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 22:40, 6.03.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (58 dBuV) Max at: 71 kHz MIN: 11 kHz % above 75 kHz: 7,7092 Acquired: 2025/03/06 22:38:59 Total samples: 10040 Equivalent time: 0:08:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,0 dBr MIN: 5,9 dBr AVE: 7,39 dBr % above 10,0 dBr: 0,0 Last value: 7,9 dBr (2025/03/06 22:38:59) Station: 96.90 MHz, signal: 4/5 (58 dBuV) 22:32 22:33 22:34 22:35 22:36 22:37 22:38 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality